the tcr - 4 - 48g power rack can be configured with four tcp3500 series units delivering up to 14 kw of output power. it can be mounted to a 19 inch rack systems using adaptor mounting brackets. two internal rs485 interfaces are used for control , monitoring and diagnostic information that can be supplied to a system controller. water cooling base plate makes the tcr - 4 - 48g suitable for a wide variety of industrial applications where the l iquid cooling is required. ? 19 rack with liquid - cooling base plate ? compatible with all tcp3500 psu models ? maximal configuration up to 4 units (14 kw) ? 3 - phase solid state relay for power modules ac input driving ? low inductance dc output busbars construction ? two rs485 interfaces (psus control/monitor and digital control of output voltage) ? coolant temperature (water): 0 to 35c with minimal flow rate 2 l/min. (recommended 4 l/min.) ? 3.2 touch screen di splay on front panel with smart monitoring and control menu ? input and output water temperature measurement ? auxiliary output 24 v / 120 w ? usb interfaces for system monitoring and control via pc and sw gui
2 tcr - 4 - 48g tech.support@psbel.com figure 1. 19 rack rear view C ac input connector, dc output busbars, signal connectors and coolant (water) connecting model input voltage range nominal output voltage output voltage range max output current max output power availability tcp3500 - h048g 180 C 528 vrms, 50/60 hz 48 v adjustable 10 C 50 vdc 73 adc or pulse 1 3500 w mass production tcp3500 - 1048g 180 C 528 vrms, 50/60 hz 48 v adjustable 1 0 C 50 vdc 73 adc 3500 w mass production tcp3500 - h 060g 180 C 528 vrms , 50/60 hz 60 v adjustable 2 0 C 60 vdc 65 adc or pulse 1 3500 w engineering samples tcp3500 - 1024g 180 C 528 vrms, 50/60 hz 24 v adjustable 5 C 30 vdc 145 adc 3500 w consult factory 1 psu model with pulse load operation capability 0 C 100 khz, 0 C 100% duty, 0/ iout_max . parameter description / condition min nom max unit input voltage 3 - phase, 3 wires + pe 104 - 305 / 180 - 528 v input frequency permitted variation 47 63 hz input current per line at 3 x 180 v (line to line) 56 arms output voltage adjustable or fixed (see model selection table) output power rating high line and low line 14 k w output current fixed or adjustable ( see psu models above ) efficiency typical, high line a t load above 40% 94 %
tcr - 4 - 48g 3 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 2017 bel power solutions & protection bcd.00903 _ 001 parameter description / condition specification radiated emission en55011 class a conducted emissions en55011 class a electrostatic discharge iec 61000 - 4 - 2 level 4: 8 kv contact, 15 kv air criterion b radiated electromagnetic field iec 61000 - 4 - 3 10 v/m criterion b electrical fast transient (eft)/burst iec 61000 - 4 - 4 level 3: 2/1 kv criterion b surge immunity level 3: 1 kv dm, 2 kv cm criterion b figure 2. sw gui application screen shot C data logger menu 4.1 gui (graphic user interface) and rs485 communication protocol bel power solutions provides a windows? xp/vista/win7 compatible sw user interface allowing the programming and monitoring of the tcp3500 power supplies. the sw utility can be downloaded from: belpowersolutions.com . for detailed information please see communication manual (bca.00129) or contact bel power solutions sales representative.
4 tcr - 4 - 48g tech.support@psbel.com parameter description / condition min nom max unit dimensions (w x d x h) s ee fig ure 2 482 x 670 x 110 mm weight with 4 psus installed 43 kg cooling liquid cool ed (water cool ed) base plate with water flow rate 2 4 l/min. 1 1 0 482 2 2 . 5 7 6 . 2 464 80 73.5 ? 10.5 x 6.5 (4x) cooling water input --------------------------- threaded hole g1/8" or male stud coupling 10mm o cooling water output --------------------------- threaded hole g1/8" or male stud coupling 10mm o 196 31 9 5 56 60 6 4 1 5 m 6 ( 4 x ) grounding --------------------------- threaded stud m6 ac input --------------------------- l1+l2+l3 usb port sense connector --------------------------- 24v +/- 670 max
tcr - 4 - 48g 5 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 2017 bel power solutions & protection bcd.00903 _ 001 figure 2. mechanical dimensions nuclear and medical applications - products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. technical revisions - the appearance of products, includ ing safety agency certifications pictured on labels, may change depending on the date manufactured. specifications are subject to change without notice. 6 0 1 . 5 0 . 5 2 3 1 1 6 2 9 1 5 1 3 5
|